Print Friendly, PDF & Email

Installation and Maintenance Instructions

according to Regulation DIN 82079

Ventilation System

Ventilation System

 


Information on the Manufacturer

Giebel Filtec GmbH

Giebel FilTec GmbH
Carl-Zeiss-Str. 5
74626 Bretzfeld
Germany

Phone +49 7946 944401 0
Fax +49 7946 944401 29
E-Mail info@giebel-adsorber.de

 


Product Overview

 

ebs-g1

Entlüftungssystem 08.0000.73

Entlüftungssystem 08.0000.94

ebs ebs fla ebs fbg
2 Valves  1 Valve EBS (Out only) EBS (FLA) EBS (FBG)

 

Material used:
Stainless steel, aluminium, FKM, EPDM

REACH notice:
No ingredients requiring disclosure in accordance with Regulation (EC) No 1907/2006.

 


Construction and Materials

 

     2 Valves 1 Valve EBS Out only EBS-FLA EBS-FBG
Housing material Stainless steel Stainless steel / aluminium
Seal material FKM / EPDM FKM FKM / EPDM -
Connection adsorber BSP G 1” f BSP G 1” f -
Connection valves BSP G 2” f BSP G 2” f / BSP G 1” f BSP G 2” f -
Connection system BSP G 2” f BSP G 2” f / BSP G 1” m BSP G 2” f Flange DN / ANSI
Operating temperature -40°C - +200°C

 


Technical Data

 

  ebs-g1

Entlüftungssystem 08.0000.73

Entlüftungssystem 08.0000.94

ebs ebs fla ebs fbg
  2 Valves 1 Valve  EBS Out only EBS-FLA EBS-FBG
Total weight [kg] 3,5  1,1 - 2,2 3,0 0,4 – 7,1 3,3 – 8,6
Diameter [mm] 314 230 - 314  314 DN / ANSI DN / ANSI
Height [mm] 244 109 - 244  216 DN / ANSI 280

 


Assembly and Commissioning

Assembly and Commissioning

1. Screw the venting system onto the venting pipe using a thread or flange. If it is an external thread, then screw it onto the system.
2. For for the versions with adsorber connection: Screw the adsorber into the upper thread for this purpose, oil the thread slightly beforehand.

 

 

 

 

 

 

 

 


Maintenance

1. Unscrew the adsorber.
2. Remove the venting system from the system.
3. Check valves for proper function. If they are damaged, replace the complete venting system.
4. Reassemble the venting system.

 


Risk and Hazard Analysis

1. Moist air flows into the Plant
Porous gaskets
Moist air can flow into the system at the porous points. The seals must be checked according to the maintenance schedule.

Valves damaged
Moist air can enter through the valves in the venting system if the valves do not close.

2. Venting System is damaged
Material resistance
The ambient and operating conditions should be taken into account when making the selection. Aggressive environmental conditions or liquid in the tank can damage the venting system.

Temperature range
The ambient and operating temperatures should not exceed or fall below the specified range, otherwise the ventilation system may be damaged.

Improper handling
Incorrect or improper handling can damage the ventilation system. The recommended installation must be observed.

Strong vibrations
Strong vibrations of the plant can damage the venting system.

3. Overpressure or Underpressure is built up
Air flow rate too high
If the air volume is too high, overpressure can build up in the tank. The characteristics of the venting system must be observed.

Valves are stuck
Certain substances in the air can cause the valves to stick at the beginning after a long period of unused storage and build up increased overpressure.

Valves are damaged
If the outlet valves no longer close because they are damaged or impaired by impurities, humid air may enter the tank.

Thread of the accessory part is damaged
When mounting the accessory on the system, the threads must be lightly moistened with oil. Failure to lubricate the threads can lead to rubbing of the individual thread and is no reason for complaint.

Thread of the Adsorber and Accessories is damaged

4. Thread of the Adsorber and Accessories is damaged
When mounting the adsorber as well as the valve part on the system, the threads must be slightly wetted with oil. Failure to lubricate the threads can lead to rubbing of the individual threads and is no reason for complaint.

 

 


Maintenance Plan

1. Visual Inspection of the Venting System

Check    The venting system must be checked visually for damage. Damage can occur due to various environmental or operating conditions or improper handling.
Cycle    Annually
Measures    If the venting system shows signs of damage, it should be replaced to ensure full functionality.

2. Ventile auf Verklemmung prüfen

Check    The venting system must be checked visually for contamination. To ensure long-term functionality, the valve should be checked for freedom of movement.
Cycle    Annually
Measures    If the valves do not open and close, replace the venting system with a new one to ensure proper functioning.

 


Contact and sales partner

Contact our contact persons and sales partners

We're here for you

You will receive an offer on the same day.
We are happy to advise you on short notice via video or
realize a personal appointment within one week.
You will receive a standard GIEBEL Adsorber within a week.

 

GIEBEL FilTec GmbH
Carl-Zeiss-Str. 5 | 74626 Bretzfeld | Germany
Phone: +49 79 46 94 44 01-0
E-Mail: info@giebel-adsorber.de